The program allows to import an SCD file (System Configuration Description) and visualize all configured GOOSE data flows among devices in the graphical connection diagram. In case of a large system the connection diagram may not fit to a single screen but the tool allows for an easy navigation in the context of any data flow: to a chosen IED, a chosen source data or a chosen destination.
GOOSE data flow can be also presented in the form of a list of all outgoing and all incoming data - with the possibility to use IED filters on both ends. The produced list can be exported into a text file.
61850 GOOSE System Viewer can be used for online monitoring of GOOSE communication in the running installation. In online mode the connections on the diagram and the transmissions in the list are marked with colors that describe whether:
- GOOSE transmission proceeds correctly with source and destination data marked with green background,
- GOOSE transmission has stopped (old data),
- an erroroneus frame has been detected,
- there is no transmission,
while any selected connection is distinguished with blue color.
61850 GOOSE System Viewer will be offered as an optional program to 61850 Avenue toolset (extended license price).
Presentation material of the 61850 GOOSE System Viewer tool (także wersja polska)
Leaflets of 61850 GOOSE System Viewer
To order or request additional information please contact INFO TECH directly or |
Special discount to schools and universities.
Please
- Details
- Category: Products
- Hits: 6839
ProtAn for Ethernet: Industrial Protocols Analyzer
Features
- transparent, real-time capturing of all data packets on the wire
- real-time parsing according to selected protocol
- different capturing stop conditions
- configurable packet filtering
- timestamps (1µs resolution), IP addresses, ports, ...
- packet data presentation in hex and ASCII form
- range of packets in time plot (inter-packets intervals)
- telecontrol protocols interpreter (DNP 3.0 over TCP/IP, IEC104, MODBUS over TCP/IP)
- universal protocol parser for frame detection of unsupported protocols
- offline analysis of captured data loaded from a disk file
Leaflets of testing tools for legacy protocols - ProTester & ProtAn
Product options and prices
ProtAn for Ethernet (DNP on TCP/IP, IEC104, MODBUS on TCP/IP, Universal) | 765 EUR |
ProtAn for Ethernet (IEC104, Universal) | 440 EUR |
To order or request additional information please contact INFO TECH
- Details
- Category: Products
- Hits: 8139
ProtAn Lite: lite but powerfull serial asynchronous protocol analyzer
Features
- analysis of serial communication (binary and ASCII protocols)
- RS232 network support
- baud rates up to 115200 bps
- two serial ports required - connection diagram
- telecontrol protocols interpreter (DNP 3.0, IEC101, IEC103, MODBUS RTU and MODBUS ASCII)
- universal protocol parser for frame detection of unsupported protocols
- extensive logging feature
- on request: plug-in specification for custom protocol interpreter development
See also the full version: ProtAn
To order or request additional information please contact INFO TECH
Serial asynchronous protocol analyser - real time with 0.1ms resolution
Features
transparent, real-time analysis of serial communication (binary and ASCII protocols)
- no external power supply - powered from USB line
- RS232 and RS485 networks support
- galvanic isolation from the analyzed network
- baud rates up to 115200 bps
- 0.1ms resolution of time stamps for characters and control line status changes
- flow control lines monitoring
- physical layer errors detection (parity, framing)
- ProtAn hardware module is CE Certified
- telecontrol protocols interpreter (DNP 3.0, IEC101, IEC103, MODBUS RTU and MODBUS ASCII)
- universal protocol parser for frame detection of unsupported protocols
- extensive logging feature
- on request: plug-in specification for custom protocol interpreter development
Product options and prices
ProtAn Modbus | Device with universal protocol parser + Modbus RTU, Modbus ASCII and Data Logger | 695 EUR |
ProtAn DNP | Device with universal protocol parser + DNP 3.0 and Data Logger | 695 EUR |
ProtAn IEC | Device with universal protocol parser + IEC 101, IEC 103 and Data Logger | 695 EUR |
ProtAn FullSet | Device with universal protocol parser + Modbus RTU, Modbus ASCII, DNP 3.0, IEC 101, IEC 103 and Data Logger | 1395 EUR |
Available additional protocol parsers (e.g. SPA-bus, PowerBus, ...) - upon request. Unsupported protocol parsers can be developed upon an order in 3 weeks. |
Additional information
To order or request additional information please contact INFO TECH directly or
Ultimate MASTER and SLAVE station simulators - DNP3.0, IEC101, IEC103, IEC104, SPA, ModBus ... on serial and TCP/IP
Leaflets of testing tools for legacy protocols - ProTester & ProtAn
Features:
- currently supported protocols: DNP 3.0, IEC 60870-5-101 (balanced and unbalanced), IEC 60870-5-103, IEC 60870-5-104, SPA-bus, ModBus
- easy and intuitive visual creation of test scenarios - no script language to learn
- inexpensive tool for communication system testing, cheaper and easier to use than SCADA system
- with separate DataView window presenting real-time status of application data
- perfect for troubleshooting - in 'Step By Step' mode operates just like a debugger!
- perfect for stress tests - provides extensive logging and statistics
- fully configurable behavior of master station including requests, responses, time dependencies, user actions etc. - unique features compared to competitive tools available on the market
- fully configurable behavior of slave station including data space definition, automatic and manual data changes, generation of events, time dependencies etc. - unique features compared to competitive tools available on the market
- possibility of introducing several types of message errors and deviations from protocol procedures
- ideal for design engineer, tester, system integrator and commissioning engineer
- support of serial communication over RS323 lines, also with RS485 and optical converters
- serial baud rates up to 115200 bps
- support for modems
- support of communication over TCP/IP/Ethernet
- license protected with security adapter - dongle
Prices:
ProTester DNP Master | Master Station Simulator for DNP 3.0 protocol (on serial and on TCP/IP) | 590 EUR |
ProTester IEC-101 Master | Master Station Simulator for IEC 60870-5-101 protocol (on serial and on TCP/IP) | 590 EUR |
ProTester IEC-103 Master | Master Station Simulator for IEC 60870-5-103 protocol (on serial and on TCP/IP) | 590 EUR |
ProTester IEC-104 Master | Master Station Simulator for IEC 60870-5-104 protocol (TCP/IP) | 590 EUR |
ProTester SPA Master | Master Station Simulator for SPA-bus protocol (on serial and on TCP/IP) | 200 EUR |
ProTester ModBus Master | Master Station Simulator for ModBus protocol (ASCII, RTU on serial and on TCP/IP) | 200 EUR |
ProTester DNP Slave | Slave Station Simulator for DNP 3.0 protocol (on serial and on TCP/IP) | 380 EUR |
ProTester IEC-104 Slave | Slave Station Simulator for IEC 60870-5-104 protocol (on TCP/IP) | 380 EUR |
ProTester SPA Slave | Slave Station Simulator for SPA-bus protocol (on serial and on TCP/IP) | 200 EUR |
ProTester ModBus Slave | Slave Station Simulator for ModBus protocol (ASCII, RTU on serial and on TCP/IP) | 200 EUR |
ProTester 3 x 3 | 3 selected protocols, 3 security adapters programmed for all chosen protocols | Ask for price |
* W sprawie cen w PLN, prosimy o When ordering ProTester tool for multiple protocols, please |
||
Support for further protocols is under development, please |
To order or request additional information please contact INFO TECH directly or |